: It supports professional features like two-stage piercing , Fly-cut , frog-leap , and auto-focus adjustment .
: Low-level active, supporting both Normally Open (NO) and Normally Closed (NC) configurations. 8 Common Outputs : Relay outputs rated for 30V DC / 5A .
: 2 DA outputs (0–10V, 50mA) and 1 PWM output (5V/24V selectable) for laser modulation. Hardware Installation bcl 4562 manual
: The height control unit (BCS100) is often integrated with the BCL 4562 via Ethernet for automated focus management.
The BCL 4562 board acts as the physical interface between the BMC1603 motion control card and the laser machine hardware. : 24V DC / 2A. : It supports professional features like two-stage piercing
: Proper grounding is essential to prevent signal interference during high-frequency pulse operations. Operational Features
: Supports X, Y1, and Y2 axes pulse output with a maximum frequency of 3MHz . : 2 DA outputs (0–10V, 50mA) and 1
: The board should be mounted securely in the machine's control cabinet. Ensure the environment is maintained between 0–55°C with no condensation.